LittaTrap™ FC
Storm Drain Inlet Protection

Meet Full Trash Capture Stormwater Regulations in California

The LittaTrap™ Full Capture (FC) inlet filter is an innovative trash control device that captures all particles five millimeters or larger. It is a durable catch basin filter that is adaptable and flexible to fit the most challenging catch basin structures, and can be installed easily inside grate and curb inlet units.

The LittaTrap™ FC has been verified by MVCAC to ensure that inspection and treatment for the purpose of minimizing mosquito production is possible by MVCAC operation.

The LittaTrap™ Full Capture (FC) is California Water Board Full Trash Capture Certified by the CA State Water Board and is now available in California to meet stormwater regulations.

TALK TO US ABOUT A FREE LITTATRAP PILOT TODAY.

A LittaTrap FC installed into a catchpit
Certified Full Capture Device by California State Water Board

Full Trash Capture with Full Capture Liner

The EnviroPod™ LittaTrap™ FC model is installed with a Full Capture Liner for complete capture of gross pollutants 5mm or larger. Note - The EnviroPod™ LittaTrap™ FC model is Full Capture certified using the FC 4.8 mm x 3.9 mm mesh liner only in California.

LittaTrap Full Capture insert liner

Adjustable and Flexible

With fewer parts and a lighter frame, the installation process is easy and saves you time.

Hinged Vector Port Seal (HVPS)

Approved Mosquito Vector Control (MVCAC) access hatch is an additional component required for (MVCAC) approval in California.

Easy to maintain

The patented batten basket allows easy hand maintenance when full or at capacity.

Lightweight & Durable

The lightweight yet durable design of the LittaTrap™ FC is a safer and a longer lasting product than the alternatives.

Certified Full Capture Device by California State Water Board

The LittaTrap™ Full Capture (FC) model is a modular, cost effective catch basin inlet filter system designed to assist municipalities meet stormwater quality regulatory and trash management requirements.

  • Complete capture of gross pollutants 5mm or larger
  • Long-lasting performance
  • Supported by an eight year limited waranty
  • Globally tested and installed
Adjustable Seals
Structural Support Brackets
Full Trash Capture with Full Capture Liner
A cut-away diagram of a LittaTrap FC inside a concrete catch pit

Inlet Configurations

LIttaTrap drain grate with drain filter

Grate Inlet

The innovative design of the LittaTrap™ allows for installation across a wide range of grate inlets. No two catch basins are the same which makes other catch basin inserts difficult or expensive to install. The LittaTrap™ has standard sizes and flexibility using simple-to-use seal kits allows for professional and high-performance installations.

LittaTrap FC Inlet Filter Curb Entry

Curb Inlet

The advantage of using a LittaTrap™ is the modular design. This allows for standard units to be installed on any curb inlet infrastructure, despite the field constraints.

Manhole inlet filter

Manhole Inlet

The LittaTrap™ can be installed easily within a range of round stormwater infrastructure. We use a bracket which is as easy to install as the LittaTrap™ itself. The round seal kits can then be used to finish off the installation that looks professional and provides optimal flow of water into the system.

EnviroPod™ LittaTrap™ FC models and sizes

-
-
-
Length
Width
Length
Width
Length
Width
Inch
18” x 18”
LTFC4545
17.1
15.4
15.4
20.6
20.6
12.0
12.0
15.7
24” x 24”
LTFC6060
22.4
15.4
20.2
25.3
25.3
17.3
17.3
15.7
36” x 24”
LTFC9060
34.3
32.0
32.0
37.1
22.7
920
17.3
15.7
Case Studies
A successful collaboration with stakeholders ensured the project met California State Water Board Full Trash Capture requirements.
National Retail Store
Read Case Study
"I would strongly recommend EnviroPod to anyone who needs help with achieving compliance with the Trash Amendments.” Jim Merid, Environmental Services Manager
City of Huntingdon Beach
Read Case Study
Five kg's of plastic pellets captured from one LittaTrap™ in a 12 month monitoring period
Medical Plastics
Read Case Study